AdelWiggins W900 Series Flexible Connector Installation PDF Print E-mail

adel.gifAfter ferrules have been attached to tubes by swaging or welding,
installation is made as follows:


colordiagramlabledrgb.gif  

  1. Install "O" Ring seal on each ferrule (lubricate before installing).
  2. Install body on one ferrule.
  3. Pull body back over other ferrule.
  4. Install clamp assembly on body.
  5. Engage latch assembly.
  6. Close into locked position.


Note: Ferrules are permanently attached to the tube by either welding or swaging.
For complete information on swaging, see Adel Wiggins Installation Manual WIM-lll.